Noise Sources

Noise Sources

Description

VDI Noise Sources (NS) offer high Excessive Noise Ratio (ENR) performance across full waveguide bands up to 220 GHz. VDI Noise Sources include waveguide isolators to improve the match between the NS and the DUT and are configured with a +28V voltage bias port, compatible with many spectrum analyzers or noise figure analyzers. Additional noise sources are under development. 

VDI Noise Sources can be used to measure the noise figure of amplifiers using a Keysight EXA or similar spectrum analyzer with the Noise Figure Measurement software, VDI down-converter (VDI SAX), and an external LO signal generator. 

NSDiagram


VDI Noise Source Specifications

VDI Part Number
 WR15NS 

 
 WR12NS 

 
 WR10NS 

 
 WR8.0NS 

 WR6.5NS  
 WR5.1NS 
 
 WR4.3NS  WR3.4NS 
Frequency Band (GHz)50-7560-9075-11090-140110-170140-220170-260220-330
Waveguide InterfaceWR-15WR-12WR-10WR-8.0WR-6.5WR-5.1WR-4.3WR-3.4
ENR (dB, typical)*17151510108.55.55.5


                                  *
VDI to include an appropriately formatted ENR file (for use on a Keysight EXA or similar analyzer) in the shipped
                          documentation.

 
  
General Specifications for VDI Noise Sources
 DescriptionSpecification
DC Bias Voltage (V)+28 ±1
Current Draw (mA)<10
Bias Voltage Connector2.92mm(f)*
Maximum Weight (lbs.)~0.1 
Isolator Return Loss (Typical)20 dB
Output FlangeUG-387/U-M**
Operating Temperature (Typical / Recommended)25°C / 20-30°C

*VDI to include a SMA(m) to BNC(f) adapter. 
**VDI Noise Sources include Compact Isolators from MHC. MHC Isolators
 have
slightly rotated output waveguide. The impact of the rotated waveguide
 is often 
negligibleClick here for more information on the rotated waveguide.

 Contact vdirfq@vadiodes.com for more information. 

Scroll to Top